DTC DETECTION LOGIC
The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst 1 causes the longer switching time. To judge the malfunctions of heated oxygen sensor 2, ECM monitors whether the maximum voltage of the sensor is sufficiently high during various driving conditions such as fuelcut.
DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
P0137 | Heated oxygen sensor 2 circuit low voltage | The maximum voltage from the sensor does not reach the specified voltage. |
|
DTC CONFIRMATION PROCEDURE
1.INSPECTION START
Do you have CONSULT?
YES >> GO TO 2.
NO >> GO TO 5.
2.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION: For better results, perform "DTC WORK SUPPORT" at a temperature of 0 to 30C (32 to 86F).
>> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
If not, warm up engine and go to next step when "COOLAN TEMP/S" indication reaches 70C (158F).
NOTE: It will take at most 10 minutes until "COMPLETED" is displayed.
Which is displayed on CONSULT screen?
OK >> INSPECTION END
NG >> Proceed to EC, "Diagnosis Procedure".
CAN NOT BE DIAGNOSED>>GO TO 4.
4.PERFORM DTC CONFIRMATION PROCEDURE AGAIN
>> GO TO 3.
5.PERFORM COMPONENT FUNCTION CHECK
Perform component function check. Refer to EC, "Component Function Check".
NOTE: Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Proceed to EC, "Diagnosis Procedure".
1.PERFORM COMPONENT FUNCTION CHECKI
Without CONSULT
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 2.
2.PERFORM COMPONENT FUNCTION CHECKII
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 3.
3.PERFORM COMPONENT FUNCTION CHECKIII
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC, "Diagnosis Procedure".
1.HECK GROUND CONNECTION
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CLEAR THE MIXTURE RATIO SELFLEARNING VALUE
Is the 1st trip DTC P0171 detected? Is it difficult to start engine?
YES >> Perform trouble diagnosis for DTC P0171. Refer to EC, "DTC Logic".
NO >> GO TO 3.
3.CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
5. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair open circuit, short to ground or short to power in harness or connectors.
4.CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check the continuity between HO2S2 harness connector and ECM harness connector.
2. Check the continuity between HO2S2 harness connector ground or ECM harness connector and ground.
3. Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair open circuit, short to ground or short to power in harness or connectors.
5.CHECK HEATED OXYGEN SENSOR 2
Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 6.
6.REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to EX, "Exploded View"
CAUTION:
>> INSPECTION END
7.CHECK INTERMITTENT INCIDENT
Refer to GI, "Intermittent Incident".
>> INSPECTION END
1.INSPECTION START
Do you have CONSULT?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK HEATED OXYGEN SENSOR 2
With CONSULT
"HO2S2 (B1)" should be above 0.68 V at least once when the "FUEL INJECTION" is +25%.
"HO2S2 (B1)" should be below 0.36 V at least once when the "FUEL INJECTION" is −25%.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 6.
3.CHECK HEATED OXYGEN SENSOR 2I
Without CONSULT
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 4.
4.CHECK HEATED OXYGEN SENSOR 2II
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 5.
5.CHECK HEATED OXYGEN SENSOR 2III
Check the voltage between ECM harness connector terminals under the following condition.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 6.
6.REPLACE HEATED OXYGEN SENSOR 2
Replace malfunctioning heated oxygen sensor 2. Refer to EX, "Exploded View".
CAUTION:
>> INSPECTION END
How to select piston and bearing
Description
Selection points
Selection parts
Selection items
Selection methods
Between cylinder block and
crankshaft
Main bearing
Main bearing grade (bearing
thickness)
Determined by match of cylinder
block bearing housing
grade (inner diameter of housi ...
Diagnosis system (EPS control unit)
CONSULT Function
FUNCTION
CONSULT can display each diagnostic item using the diagnostic test modes
shown following.
*: The following diagnosis information is erased by erasing.
DTC
Freeze frame data (FFD)
ECU IDENTIFICATION
Displays the part number stored in the con ...