OVERALL SEQUENCE
Before performing a generator test, make sure that the battery is fully charged. A 30-volt voltmeter and suitable test probes are necessary for the test.
DETAILED FLOW
1.PRELIMINARY INSPECTION
Perform the preliminary inspection. Refer to CHG "Diagnosis Procedure".
>> GO TO 2.
2.STOP POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
Stop the operation of the power generation voltage variable control in either of the following procedures:
>> GO TO 3.
3.INSPECTION WITH CHARGE WARNING LAMP (IGNITION SWITCH IS TURNED ON)
When ignition switch is turned ON.
Does the charge warning lamp illuminate?
YES >> GO TO 4.
NO >> GO TO 10.
4.INSPECTION WITH CHARGE WARNING LAMP (IDLING)
Start the engine and run it at idle
Does the charge warning lamp turn OFF?
YES >> GO TO 5.
NO >> GO TO 6.
5.INSPECTION WITH CHARGE WARNING LAMP (ENGINE AT 2,500 RPM)
Increase and maintain the engine speed at 2,500 rpm.
Does the charge warning lamp illuminate?
YES >> GO TO 8.
NO >> Inspection End.
6."L" TERMINAL CIRCUIT (SHORT) INSPECTION
Check terminal "L" circuit for (short). Refer to CHG "Diagnosis Procedure".
Is the inspection result normal?
YES >> GO TO 7.
NO >> Repair as needed.
7."S" TERMINAL CIRCUIT INSPECTION
Check terminal "S" circuit. Refer to CHG "Diagnosis Procedure".
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair as needed.
8.MEASURE "B" TERMINAL VOLTAGE
Start engine. With engine running at 2,500 rpm, measure "B" terminal voltage.
What voltage does the measurement result show?
Less than 13.0 V>>GO TO 9.
More than 16.0 V>>Replace generator. Refer to CHG "Removal and Installation".
9."B" TERMINAL CIRCUIT INSPECTION
Check "B" terminal circuit. Refer to CHG "Diagnosis Procedure".
Is the inspection result normal?
YES >> Replace generator. Refer to CHG "Removal and Installation".
NO >> Repair as needed.
10.INSPECTION WITH CHARGE WARNING LAMP (IGNITION SWITCH IS ON)
1. Disconnect generator connector and apply ground to "L" terminal.
2. Turn the ignition switch ON.
Does the charge warning lamp illuminate?
YES >> Replace generator. Refer to CHG "Removal and Installation".
NO >> GO TO 11.
11.CHECK "L" TERMINAL CIRCUIT (OPEN)
Check "L" terminal circuit (OPEN). Refer to CHG "Diagnosis Procedure".
>> Repair as needed.