1.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
Water should not exist.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace harness connector.
2.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 3.
3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace errordetected parts
4.CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
*: With A/C models
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair short to ground or short to power in harness or connectors.
5.CHECK COMPONENTS
Check the following.
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace malfunctioning component.
6.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
Is the inspection result normal?
YES >> GO TO 7.
NO >> Repair or replace errordetected parts.
7.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
2. Also check harness for short to ground and to power.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair or replace errordetected parts.
8.CHECK RUBBER TUBE
Is the inspection result normal?
YES >> GO TO 9.
NO >> Clean the rubber tube using an air blower, repair or replace rubber tube.
9.CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> GO TO 10.
NO >> Replace EVAP canister vent control valve. Refer to FL, "Removal and Installation".
10.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> GO TO 11.
NO >> Replace EVAP control system pressure sensor. Refer to FL, "Removal and Installation".
11.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
Does water drain from EVAP canister?
YES >> GO TO 12.
NO >> Check intermittent incident. Refer to GI45, "Intermittent Incident".
12.CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 1.6 kg (3.5 lb).
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> GO TO 13.
13.DETECT MALFUNCTIONING PART
Check the following.
>> Repair hose or replace EVAP canister. Refer to FL, "Removal and Installation".