Diagnosis Procedure
1.CHECK AUTOMATIC LOCK/UNLOCK SELECT SETTING IN WORK SUPPORT
Refer to BCS "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK)".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Set Lock Only or Lock/Unlock in WORK SUPPORT.
2.CHECK AUTOMATIC DOOR LOCK SELECT SETTING IN WORK SUPPORT
Refer to BCS "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK)".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Set VH SPD in AUTOMATIC DOOR LOCK SELECT.
3.REPLACE BCM
Is the result normal?
YES >> Inspection End.
NO >> Check intermittent incident. Refer to GI "Intermittent Incident".
Diagnosis Procedure 1.CHECK AUTO LOCK SET SETTING IN WORK SUPPORT Select INTELLIGENT KEY of BCM using CONSULT. Select AUTO LOCK SET in WORK SUPPORT mode. Check AUTO LOCK SET setting in WORK ...
Diagnosis Procedure 1.CHECK AUTOMATIC LOCK/UNLOCK SELECT SETTING IN WORK SUPPORT Select DOOR LOCK of BCM using CONSULT. Select AUTOMATIC LOCK/UNLOCK SELECT in WORK SUPPORT mode. Check AUTOM ...
EVAP control system pressure sensor
Exploded View
1. EVAP control system pressure sensor 2. O-ring 3. EVAP canister
Removal and Installation
NOTE:
The EVAP canister system pressure sensor can be removed without removing the
EVAP canister.
REMOVAL
Remove the EVAP canister protector cover.
Disconnect EVAP canister purg ...
Side curtain air bag module
Exploded View
1. Side curtain air bag module 2. Side curtain air bag module connector A.
Adhesive tape area
Removal and Installation
REMOVAL
CAUTION:
Before servicing, turn ignition switch OFF, disconnect both
battery terminals and wait at least three
minutes.