Description
Diagnosis Procedure
1.CHECK WASHER FLUID LEVEL SWITCH
Perform a unit check for the washer fluid level switch. Refer to MWI "Component Inspection".
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace washer fluid level switch. Refer to WW "Exploded View".
2.CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT
Check the washer fluid level switch signal circuit. Refer to MWI "Diagnosis Procedure".
Is the inspection result normal?
YES >> Replace combination meter. Refer to MWI "Removal and Installation".
NO >> Repair or replace harness or connector.
REMOVAL AND INSTALLATION
Description The oil pressure warning lamp stays of when the ignition switch is turned ON. Diagnosis Procedure 1.CHECK COMBINATION METER OIL PRESSURE WARNING LIGHT 1. Select METER/M&A on CONS ...
Removal and Installation REMOVAL 1. Disconnect the negative battery terminal. Refer to PG "Removal and Installation". 2. Remove cluster lid A. Refer to IP "Removal and Installati ...
EVAP control system pressure sensor
Exploded View
1. EVAP control system pressure sensor 2. O-ring 3. EVAP canister
Removal and Installation
NOTE:
The EVAP canister system pressure sensor can be removed without removing the
EVAP canister.
REMOVAL
Remove the EVAP canister protector cover.
Disconnect EVAP canister purg ...
P0733 3GR Incorrect ratio
Description
This malfunction is detected when the A/T does not shift into 3GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...