System
RELAY CONTROL SYSTEM
RELAY CONTROL SYSTEM : System Diagram
RELAY CONTROL SYSTEM : System Description
IPDM E/R activates the internal control circuit to perform the relay ON-OFF
control according to the input signals
from various sensors and the request signals received from control units via CAN
communication.
CAUTION:
To prevent damage to the parts, IPDM E/R integrated relays cannot be removed.
POWER CONSUMPTION CONTROL SYSTEM
POWER CONSUMPTION CONTROL SYSTEM : System Diagram
POWER CONSUMPTION CONTROL SYSTEM : System Description
OUTLINE
- IPDM E/R incorporates a power consumption control function that reduces
the power consumption according
to the vehicle status.
- IPDM E/R changes its status (control mode) with the sleep wake up signal
received from BCM via CAN communication.
Normal mode (wake-up)
- CAN communication is normally performed with other control units.
- Individual unit control by IPDM E/R is normally performed.
Low power consumption mode (sleep)
- Low power consumption control is active.
- CAN transmission is stopped.
SLEEP MODE ACTIVATION
- IPDM E/R judges that the sleep-ready conditions are fulfilled when the
ignition switch is OFF and none of the
conditions below are present. Then it transmits a sleep-ready signal (ready)
to BCM via CAN communication.
- Outputting signals to actuators
- Switches or relays operating
- Output requests are being received from control units via CAN
communication.
- IPDM E/R stops CAN communication and enters the low power consumption
mode when it receives a sleep
wake up signal (sleep) from BCM and the sleep-ready conditions are
fulfilled.
WAKE-UP OPERATION
- IPDM E/R changes from the low power consumption mode to the normal mode
when it receives a sleep
wake-up signal (wake up) from BCM or any of the following conditions is
fulfilled. In addition, it transmits a
sleep-ready signal (not-ready) to BCM via CAN communication to report the
CAN communication start.
- Ignition switch ON
- An output request is received from a control unit via CAN
communication.