REMOTE KEYLESS ENTRY SYSTEM : System Diagram
REMOTE KEYLESS ENTRY SYSTEM : System Description
The remote keyless entry system can be locked and unlocked by pressing door lock and unlock button of keyfob.
DOOR LOCK AND UNLOCK OPERATION
OPERATION CONDITION
OPERATION AREA
To ensure that the keyfob works effectively, use within 10 m (33ft) range of the vehicle, however the operable range may differ according to surroundings.
SELECTIVE UNLOCK OPERATION
When door lock is unlocked, pressing LOCK button on keyfob once will lock all doors. When door lock is locked, pressing UNLOCK button on keyfob will unlock driver side door. Pressing UNLOCK button on keyfob second time within 5 seconds from the first time will unlock all doors.
HAZARD AND HORN REMINDER
When the doors are locked or unlocked by keyfob, power is supplied to sound horn and flash hazard warning lamps as a reminder The hazard and horn reminder has C mode (horn chirp mode) and S mode (non-horn chirp mode).
How to Change Hazard and Horn Reminder Modes
With CONSULT
Hazard and horn reminders can be changed using "WORK SUPPORT" mode in "MULTI REMOTE ENT".
Hazard and horn reminders do not operate if any door switch is ON (any door is OPEN).
Hazard reminder can be changed using "HAZARD LAMP SET" mode in "WORK SUPPORT".
Horn reminder can be changed using "HORN CHIRP SET" mode in "WORK SUPPORT".
Refer to BCS "MULTI REMOTE ENT : CONSULT Function (BCM - MULTI REMOTE ENT)".
Without CONSULT
Refer to Owner's Manual for instructions.
AUTO DOOR LOCK OPERATION
When all doors are locked, ignition switch is OFF and key switch is OFF (mechanical key is removed from the ignition cylinder), doors are unlocked with keyfob button. When BCM does not receive the following signals within 1 minute, all doors are locked.
Auto door lock mode can be changed by "AUTO LOCK SET" mode in "WORK SUPPORT". Refer to BCS "MULTI REMOTE ENT : CONSULT Function (BCM - MULTI REMOTE ENT)".
PANIC ALARM OPERATION
When key switch is OFF (mechanical key is removed from the ignition cylinder), BCM turns ON and OFF horn and headlamp intermittently with input of PANIC ALARM signal from keyfob.
BCM outputs to headlamps and IPDM E/R for panic alarm signal (horn signal) via CAN communication lines.
The alarm automatically turns OFF after 25 seconds or when BCM receives any signal from keyfob.
Panic alarm operation mode can be changed using "PANIC ALARM SET" mode in "WORK SUPPORT".
Refer to BCS "MULTI REMOTE ENT : CONSULT Function (BCM - MULTI REMOTE ENT)".
INTERIOR LAMP TIMER OPERATION
When the following conditions occur, remote keyless entry system turns on interior lamp for 15 seconds with input of UNLOCK signal from keyfob. For detailed description, refer to INL "INTERIOR ROOM LAMP CONTROL SYSTEM : System Description".