Precaution for Leak Detection Dye
- The A/C system contains a fluorescent leak detection dye used for
locating refrigerant leaks. An ultraviolet
(UV) lamp is required to illuminate the dye when inspecting for leaks.
- Always wear fluorescence enhancing UV safety goggles to protect your
eyes and enhance the visibility of
the fluorescent dye.
- A compressor shaft seal should not be repaired because of dye seepage.
The compressor shaft seal should
only be repaired after confirming the leak with an electronic refrigerant
leak detector (J-41995).
- Always remove any dye from the leak area after repairs are complete to
avoid a misdiagnosis during a future
service.
- Do not allow dye to come into contact with painted body panels or
interior components. If dye is spilled,
clean immediately with the approved dye cleaner. Fluorescent dye left on a
surface for an extended period of
time cannot be removed.
- Do not spray the fluorescent dye cleaning agent on hot surfaces (engine
exhaust manifold, etc.).
- Do not use more than one refrigerant dye bottle (1/4 ounce / 7.4 cc) per
A/C system.
- Leak detection dyes for HFC-134a (R-134a) and HC-12 (R-12) A/C systems
are different. Do not use HFC-
134a (R-134a) leak detection dye in R-12 A/C systems or HC-12 (R-12) leak
detection dye in HFC-134a (R-
134a) A/C systems or A/C system damage may result.
- The fluorescent properties of the dye will remain for over three (3)
years unless a compressor failure occurs.