Component Function Check
1.CHECK PARKING BRAKE SWITCH OPERATION
Check that brake warning lamp in combination meter turns ON/OFF when parking brake is actuated.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to BRC "Wiring Diagram".
1.CONNECTOR INSPECTION
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair or replace as necessary.
2.CHECK PARKING BRAKE SWITCH
Check parking brake switch. Refer to BRC "Component Inspection".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace parking brake switch. Refer to PB "Exploded View".
3.CHECK PARKING BRAKE SWITCH SIGNAL
With CONSULT.
Is the inspection result normal?
YES >> Refer to BRC "Work Flow".
NO >> GO TO 4.
4.CHECK PARKING BRAKE SWITCH CIRCUIT
4. Check continuity between combination meter connector and ground.
Is the inspection result normal?
YES >> Replace combination meter. Refer to MWI"Removal and Installation" (type A) or MWI "Removal and Installation" (type B).
NO >> Repair or replace malfunctioning components.
Component Inspection
1.CHECK PARKING BRAKE SWITCH
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace parking brake switch. Refer to PB "Exploded View".