Diagnosis Procedure
1.CHECK HAZARD ANSWER BACK SETTING IN WORK SUPPORT
Refer to BCS "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIGENT KEY)".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Set the Lock Only, Unlock Only or Lock/Unlock in HAZARD ANSWER BACK.
2.CHECK ANS BACK I-KEY LOCK SETTING IN WORK SUPPORT
Refer to BCS "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIGENT KEY)".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Set the Horn Chirp or Buzzer in ANS BACK I-KEY LOCK.
3.CHECK ANS BACK I-KEY UNLOCK SETTING IN WORK SUPPORT
Refer to BCS "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIGENT KEY)".
Is the inspection result normal?
YES >> GO TO 4.
NO >> Set the On in ANS BACK I-KEY UNLOCK.
4.CHECK HAZARD FUNCTION
Check hazard function.
Refer to DLK "Component Function Check".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace the malfunctioning parts.
5.CHECK INTELLIGENT KEY WARNING BUZZER
Check Intelligent Key warning buzzer.
Refer to DLK "Component Function Check".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace the malfunctioning parts.
6.REPLACE BCM
Is the result normal?
YES >> Inspection End.
NO >> Check intermittent incident. Refer to GI "Intermittent Incident".