1. CHECK FRONT WIPER (AUTO STOP) SIGNAL
1. Select FR WIPER STOP of BCM (WIPER) data monitor item.
2. Operate the front wiper.
3. Check that FR WIPER STOP changes from ON to OFF according to the wiper
position.
Is the inspection result normal?
YES >> Front wiper auto stop signal circuit is normal.
NO >> Refer to WW "Diagnosis Procedure".
Regarding Wiring Diagram information, refer to WW "Wiring Diagram".
1. CHECK FRONT WIPER MOTOR (AUTO STOP) OUTPUT VOLTAGE
1. Turn the ignition switch ON.
2. Check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES >> Check for intermittent failure.
NO >> GO TO 2
2. CHECK FRONT WIPER MOTOR (AUTO STOP) SHORT CIRCUIT
1. Turn the ignition switch OFF.
2. Disconnect IPDM E/R and front wiper motor.
3. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES >> Repair or replace harness.
NO >> GO TO 3.
3. CHECK FRONT WIPER MOTOR (AUTO STOP) CIRCUIT CONTINUITY
Check continuity between IPDM E/R harness connector and front wiper motor harness connector.

Is the inspection result normal?
YES >> Replace front wiper motor. Refer to WW "WIPER DRIVE ASSEMBLY : Removal and Installation".
NO >> Repair or replace harness.

Diagnosis Procedure Regarding Wiring Diagram information, refer to WW "Wiring Diagram". 1. CHECK FRONT WIPER MOTOR GROUND CIRCUIT 1. Turn the ignition switch OFF. 2. Disconnect front wip ...
Air breather hose
Removal and Installation
REMOVAL
Remove air duct (inlet). Refer to EM "Exploded View".
Remove air breather hose from transaxle assembly.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
Check that air breather hose is not collapsed or blocked due to ...
Operation inspection
Work Procedure
The purpose of the operation inspection is to check that the individual
system operates normally.
Check condition : Engine running at normal operating temperature.
1.CHECK FRONT BLOWER MOTOR