1.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
Water should not exist.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace harness connector.
2.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 3.
3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace errordetected parts
4.CHECK SENSOR POWER SUPPLY CIRCUIT
Check harness for short to power and short to ground, between the following terminals.
*: With A/C models
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair short to ground or short to power in harness or connectors.
5.CHECK COMPONENTS
Check the following.
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace malfunctioning component.
6.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
Is the inspection result normal?
YES >> GO TO 7.
NO >> Repair or replace errordetected parts.
7.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
1. Check the continuity between EVAP control system pressure sensor harness connector and ECM harness connector.
2. Also check harness for short to ground and to power.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair or replace errordetected parts.
8.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace EVAP control system pressure sensor. Refer to FL, "Removal and Installation".