Nissan Versa
Sedan Service Manual
Ventilation, heater & air conditioner » Heater & air conditioning control system (HAC) » Front blower motor
Component Inspection (Blower Relay)
1.CHECK BLOWER RELAY
- Remove blower relay. Refer to PG "Terminal Arrangement".
- Check continuity between blower relay terminal 3 and 5 when
the voltage is supplied between terminal 1 and 2.


Is the inspection result normal?
YES >> Inspection End.
NO >> Replace blower relay.
Component Inspection (Front Blower Motor Resistor)
1.CHECK FRONT BLOWER MOTOR RESISTOR
- Disconnect front blower motor resistor connector.
- Check resistance between front blower motor resistor terminals. Refer to
applicable table for the normal
value.

Is the inspection result normal?
YES >> Inspection End.
NO >> Replace front blower motor resistor. Refer to HAC "Removal and
Installation".
Component Inspection (Fan Switch)
1.CHECK FAN SWITCH
- Remove front air control. Refer to HAC "Removal and Installation".
- Check continuity between front air control terminals.

Is the inspection result normal?
YES >> Inspection End.
NO >> Replace front air control. Refer to HAC "Removal and Installation".