Component Function Check
1.CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES >> Refer to BRC "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI "METER SYSTEM : System Description" (type A) and MWI "METER SYSTEM : System Description" (type B).
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type A) or MWI "Removal and Installation" (type B).